HYDRAcap-MAX-80 Ultrafiltration
Advanced ultrafiltration membrane used for RO pretreatment or direct filtration of variable source water.
Need this product?
Get pricing, availability, and expert guidance tailored to your application.
Contact Our TeamDescription
HYDRAcap-MAX-80 is used to treat a wide range of highly variable waters as either primary treatment or as pretreatment to reverse osmosis (RO) and nanofiltration (NF)
Application DataTypical Filtrate Flux Range: 20 – 65 gfd (34 – 110 l/m2/h)
Maximum Applied Feed Pressure: 73 psig (5.0 bar)3
Maximum Transmembrane Pressure 30 psig (2.0 bar)
Instantaneous Chlorine Tolerance: 5000 ppm4
Maximum Chlorine Exposure: 1,000,000 ppm-hrs
Maximum Feed Turbidity: 300 NTU5
Maximum Operating Temperature: 104 °F (40 °C)
pH Operating Range: 2.0 – 11.0
Cleaning pH Range: 1.0 – 13.0
Operating Mode: Outside to Inside Filtration Dead End or Cross flow mode
Application Data
Specifications
Model Number
HYDRAcap-MAX-80, HYDRAcap-MAX-4040
Filtrate Flow
15.7 – 51.0 gpm (3.6 – 11.6 m³/h)
Bacteria Removal
≥ 4 log
Nominal Membrane Area
1130 ft² (105 m²)
Fiber Dimensions
ID 0.024” (0.6 mm), OD 0.047” (1.2 mm)
Pore Size
0.08 micron